0102030405
Chinesische Hersteller von Mehrfach-IR-Langpassfiltern: Hohe Lichtdurchlässigkeit für präzise Temperaturmessung
| Name | 5% RABATT | 50% RABATT | HT (nm) | Tmin | Tavg | Größe (mm) | Sub | Tmax | Tavg | Spektrogramm |
|---|---|---|---|---|---|---|---|---|---|---|
| LP1200 | / | 1200 | 1300–4800 | / | ≥80 | Φ0,1~300 | Saphir |
| ||
| LP1500 | 1500 | 1600–5300 | ≥85 | Φ0,1~300 | Saphir |
| ||||
| LP1600 | / | 1600 | 1650–1700 | / | ≥90 | Φ0,1~300 | Quarz |
| ||
| / | 1600 | 1650–1660 | / | ≥90 | Φ0,1~300 | Weißes Glas |
| |||
| LP2000 | 1930 | 2000 | 2100–2800 | / | ≥85 | Φ0,1~300 | Saphir |
| ||
| LP2400 | / | 2400–11100 11100–13300 | ≥80 | / | Φ0,1~300 | Ge |
| |||
| LP2750 | 2700 | 2750 | 2800–3670 | / | ≥90 | Φ0,1~300 | Quarz |
| ||
| LP2800 | 2800 | 2950–5100 | / | ≥90 | Φ0,1~300 | ZnSe |
| |||
| LP2900 | 2900 | 3050–5100 | / | ≥90 | Φ0,1~300 | ZnSe |
| |||
| LP3200 | 3320 | 3400 | 3480–5350 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3300 | 3200 | 3300 | 3400–5000 | / | ≥90 | Φ0,1~300 | Saphir |
| ||
| LP3450 | / | 3450 | 3700–5000 | / | ≥93 | Φ0,1~300 | Ge |
| ||
| LP3500 | 3600 | 3670 | 3800–5600 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3550 | / | 3550 | 3800–5500 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3600 | / | 3600 | 3960–4800 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3650 | 3540 | 3620 | 3700–5200 | / | ≥85 | Φ0,1~300 | Saphir |
| ||
| LP3700 | / | 3700 | 4000–5500 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3730 | 0,1 | 3730 | 4400–4900 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3750 | 3750 | 3800–4900 | / | ≥90 | Φ0,1~300 | Ge |
| |||
| LP3760 | / | 3760 | 3960–4800 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3800 | / | 3800 | 4200–5500 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP3850 | / | 3850 | 4000–5000 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP4000 | 3850 | 4000 | 4100–5100 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP4250 | 4350–5000 | / | ≥85 | Φ0,1~300 | Ge |
| ||||
| LP4730 | 4730 | 4900–5150 | / | ≥80 | Φ0,1~300 | Saphir |
| |||
| LP5500 | 5500 | / | 7500–13500 | / | ≥72 | Φ0,1~300 | Saphir |
| ||
| LP6100 | / | 6100 | 6300–12600 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP6200 | / | 6200 | 6400–12600 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP6300 | / | 6300 | 6550–14500 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP6400 | / | 6400 | 6500–12600 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP6900 | 6900 | 7030 | 7200–12610 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP6500 | / | 6500 | 6800–11000 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP6750 | / | / | 7000–14000 | / | ≥80 | Φ0,1~300 | ZnSe |
| ||
| LP7150-A | 7150 | / | 8000–11000 | / | ≥90 | Φ0,1~300 | Ge | 20 |
| |
| LP7150-B | 7150 | / | 8000–12000 | / | ≥80 | Φ0,1~300 | Gib mir | 15 |
| |
| LP7200 | / | / | 10000–12600 | / | ≥90 | Φ0,1~300 | Ge | 10 |
| |
| LP7300 | 7420 | / | 8000–11000 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP7400 | / | 7400 | 8000–14000 | / | ≥80 | Φ0,1~300 | Gib mir |
| ||
| LP7500 | / | / | 8400–12500 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP7675 | 7675 | 8000–14000 | / | ≥90 | Φ0,1~300 | Ge |
| |||
| LP7700 | / | 7700 | 8000–11000 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP7730 | 7730 | / | 8000–14000 | / | ≥80 | Φ0,1~300 | Ge-Wafer |
| ||
| LP7750 | 7750 | 8100–11000 | / | ≥90 | Φ0,1~300 | Ge |
| |||
| LP7800 | / | 7800 | 8100–11000 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP7850 | / | 7850 | 8000–11000 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP7900 | / | 7900 | 8200–11000 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP7925 | / | 7925 | 8100–12600 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP7950 | / | 7950 | 8050–14000 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP8000 | / | 8000 | 8150–12000 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP8100 | / | 8100 | 8150–12000 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP8200 | 8200 | / | 9000–14000 | / | ≥80 | Φ0,1~300 | Ge-Wafer |
| ||
| LP8400 | 8400 | / | 8800–15000 | / | ≥90 | Φ0,1~300 | ZnSe |
| ||
| LP9000 | 9000 | 9500–12500 | / | ≥90 | Φ0,1~300 | Ge |
| |||
| LP9700 | 9700 | 10100 bis 15000 | / | ≥90 | Φ0,1~300 | ZnSe |
| |||
| LP9800 | / | 9800 | 10000–16300 | / | ≥90 | Φ0,1~300 | ZnSe |
| ||
| LP9900 | / | 9900 | 10000–16300 | / | ≥85 | Φ0,1~300 | ZnSe |
| ||
| LP10000 | / | 10000 | 10150–14300 | / | ≥90 | Φ0,1~300 | ZnSe |
| ||
| LP10015 | / | 10015 | 10450–14500 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP10080 | / | 10080 | 10180–13500 | / | ≥85 | Φ0,1~300 | Ge | 3 |
| |
| LP10100 | / | 10100 | 10150–14300 | / | ≥90 | Φ0,1~300 | ZnSe |
| ||
| LP10200 | / | 10200 | 10500–14000 | / | ≥85 | Φ0,1~300 | Ge | 3 |
| |
| LP10300 | / | 10100 | 10500–13000 | / | ≥85 | Φ0,1~300 | Ge | 3 |
| |
| LP10400 | / | 10325 | 10500–15000 | / | ≥90 | Φ0,1~300 | ZnSe |
| ||
| LP10500 | / | 10500 | 10700–15000 | / | ≥85 | Φ0,1~300 | ZnSe |
| ||
| LP10600 | / | 10600 | 11000–14000 | / | ≥80 | Φ0,1~300 | Ge | 5 |
| |
| LP10840 | / | 10840 | 10940–13500 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP10900 | / | 10900 | 11200–15400 | / | ≥80 | Φ0,1~300 | Ge |
| ||
| LP11050 | / | 11050 | 11200–15400 | / | ≥80 | Φ0,1~300 | Ge |
| ||
| LP11190 | / | 11190 | 11500–15700 | / | ≥80 | Φ0,1~300 | Ge |
| ||
| LP11400 | / | 11400 | 11600–12250 | / | ≥90 | Φ0,1~300 | Ge |
| ||
| LP11600 | / | 11600 | 11800–12200 | / | ≥85 | Φ0,1~300 | Ge |
| ||
| LP11700 | / | 11700 | 11900–12300 | / | ≥80 | Φ0,1~300 | Ge |
| ||
| LP11900 | / | 11900 | 12100–12500 | / | ≥75 | Φ0,1~300 | Ge |
|
1 2 3
Die obige Liste zeigt unsere aktuellen Lagerartikel.
Falls Sie nicht finden, wonach Sie suchen, bitte Kontaktieren Sie unsDie
Häufig gestellte Fragen (FAQ)
Wozu werden Langpass-Lichtfilter (LP-Filter) verwendet?
Langpassfilter sind so konstruiert, dass sie Wellenlängen oberhalb einer bestimmten Grenzfrequenz durchlassen und gleichzeitig kürzere Wellenlängen blockieren. Sie werden häufig in der Fluoreszenzmikroskopie, Spektroskopie und verschiedenen industriellen Bildgebungsverfahren eingesetzt, um spezifische Spektralbänder zu isolieren.
Wie wähle ich das richtige Substrat (Saphir, Quarz, Ge, ZnSe) für meine Anwendung aus?
Die Wahl des Substrats hängt vom erforderlichen Transmissionsbereich und der Beständigkeit gegenüber Umwelteinflüssen ab. Quarz eignet sich hervorragend für den UV- bis Nahinfrarotbereich, Saphir bietet extreme Beständigkeit und hohe Wärmeleitfähigkeit, während Germanium (Ge) und Zinkselenid (ZnSe) ideal für Anwendungen im mittleren bis fernen Infrarotbereich (IR) sind.
Können diese optischen Filter an spezifische Größen angepasst werden?
Ja. Unsere Standardgrößen reichen von Φ0,1 mm bis 300 mm, wir bieten aber auch kundenspezifische Größen, Formen und Montageoptionen an, die auf Ihre spezifischen Systemintegrationsanforderungen zugeschnitten sind.
Was bedeuten die Angaben „5% Cut On“ und „50% Cut On“?
„5 % Cut On“ bezeichnet die Wellenlänge, bei der die Transmission des Filters erstmals 5 % der absoluten Transmission erreicht. „50 % Cut On“ markiert den Übergangspunkt, an dem die Transmission 50 % des Spitzenwerts erreicht und definiert damit den nominalen Beginn des Durchlassbereichs.
Wie kann ich ein Angebot für kundenspezifische Spezifikationen anfordern?
Falls unsere Lagerartikel Ihren Anforderungen nicht entsprechen, können Sie über den Link „Kontakt“ eine Anfrage senden. Unser Ingenieurteam unterstützt Sie gerne bei der Entwicklung kundenspezifischer optischer Beschichtungen, die Ihrem gewünschten Transmissionsprofil entsprechen.